hard disk seagate barracuda 3tb

hard disk seagate barracuda 3tb hard disk seagate barracuda 3tb Hard Drives

selling unused hdd seagate barracuda 3tb sata3 model st3000dm001 due to storage upgrade.

see picture for full details

smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.17.0-7-generic] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.14 (AF)
Device Model: ST3000DM001-1CH166
Serial Number: Z1F4VLNK
LU WWN Device Id: 5 000c50 066350c35
Firmware Version: CC27
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database 7.3/5528
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Feb 28 12:49:33 2026 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
See vendor-specific Attribute list for marginal Attributes.

General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 575) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 318) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x3085) SCT Status supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 119 094 006 Pre-fail Always - 206980344
3 Spin_Up_Time 0x0003 094 093 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 099 099 020 Old_age Always - 1383
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 085 060 030 Pre-fail Always - 396574446
9 Power_On_Hours 0x0032 021 021 000 Old_age Always - 69898
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 161
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
187 Reported_Uncorrect 0x0032 036 036 000 Old_age Always - 64
188 Command_Timeout 0x0032 100 098 000 Old_age Always - 1 4 22
189 High_Fly_Writes 0x003a 081 081 000 Old_age Always - 19
190 Airflow_Temperature_Cel 0x0022 076 043 045 Old_age Always In_the_past 24 (0 168 24 20 0)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 89
193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 616698
194 Temperature_Celsius 0x0022 024 057 000 Old_age Always - 24 (0 13 0 0 0)
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 64659h+17m+09.213s
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 149463492031
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 1089507552370

SMART Error Log Version: 1
ATA Error Count: 64 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 64 occurred at disk power-on lifetime: 4309 hours (179 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 00 00 Error: UNC at LBA = 0x00000800 = 2048

Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 08 00 40 00 00:06:37.182 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:33.446 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:29.697 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:25.960 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:22.210 READ DMA EXT

Error 63 occurred at disk power-on lifetime: 4309 hours (179 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 00 00 Error: UNC at LBA = 0x00000800 = 2048

Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 08 00 40 00 00:06:33.446 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:29.697 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:25.960 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:22.210 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:18.477 READ DMA EXT

Error 62 occurred at disk power-on lifetime: 4309 hours (179 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 00 00 Error: UNC at LBA = 0x00000800 = 2048

Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 08 00 40 00 00:06:29.697 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:25.960 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:22.210 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:18.477 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:14.779 READ DMA EXT

Error 61 occurred at disk power-on lifetime: 4309 hours (179 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 00 00 Error: UNC at LBA = 0x00000800 = 2048

Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 08 00 40 00 00:06:25.960 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:22.210 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:18.477 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:14.779 READ DMA EXT
25 00 08 00 04 00 40 00 00:06:14.768 READ DMA EXT

Error 60 occurred at disk power-on lifetime: 4309 hours (179 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 00 08 00 00 Error: UNC at LBA = 0x00000800 = 2048

Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 08 00 08 00 40 00 00:06:22.210 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:18.477 READ DMA EXT
25 00 08 00 08 00 40 00 00:06:14.779 READ DMA EXT
25 00 08 00 04 00 40 00 00:06:14.768 READ DMA EXT
25 00 08 00 02 00 40 00 00:06:14.674 READ DMA EXT

SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 23233 -
# 2 Extended offline Completed without error 00% 23218 -
# 3 Short offline Completed without error 00% 23185 -
# 4 Short offline Completed without error 00% 23161 -
# 5 Short offline Completed without error 00% 23137 -
# 6 Short offline Completed without error 00% 23113 -
# 7 Short offline Completed without error 00% 23089 -
# 8 Short offline Completed without error 00% 23065 -
# 9 Short offline Completed without error 00% 23041 -
#10 Extended offline Completed without error 00% 23041 -
#11 Short offline Completed without error 00% 23017 -
#12 Short offline Completed without error 00% 22993 -
#13 Short offline Completed without error 00% 22969 -
#14 Short offline Completed without error 00% 22945 -
#15 Short offline Completed without error 00% 22921 -
#16 Short offline Completed without error 00% 22897 -
#17 Short offline Completed without error 00% 22873 -
#18 Extended offline Completed without error 00% 22873 -
#19 Short offline Completed without error 00% 22849 -
#20 Short offline Completed without error 00% 22825 -
#21 Short offline Completed without error 00% 22801 -

More in Hard Drives
(324)
More from this seller
(6)
Shipping:
  • Collection
Payment:
  • Cash
  • Paypal
  • To be arranged
Entered/Renewed:

11 months ago

Ad Views:

236

  • Report ad
SELL SOMETHING SIMILAR
Comments & Offers
4 months
@blingblingboy no thanks
4 months
€30 OFFERED